  1. How to install a new License file when the LDAP Synchronization tool is running?

    How to install a new License file when the LDAP Synchronization tool is running   Procedure Steps If a new license needs to be installed and LDAP Synchronization is being used, stop the DataConduIT services before installing the license. On...
  2. Under WBEMTEST Notification Queries fail.

    Symptom Running wbemtest everything works correctly. LNL_BADGE and LNL_CARDHOLDER are  available. You are able to run queries, but running a Notification Query you get Access Denied. Resolution This is caused because a misconfiguratio...
  3. Unable to pulse elevator outputs through DataConduIT

    Symptom Elevator outputs do not pulse when attempted through DataConduIT. However, other non-elevator outputs can be pulsed through DataConduIT. Resolution DataConduIT currently does not support the ability to pulse elevator outputs....
  4. Configuring DataConduIT's Logging Directory

    DataConduIT - Configuring the logging directory for DataConduIT   Procedure Steps To configure where the LS DataConduIT Service writes it log: Run RegEdit . Navigate to the below directory based on the server's operating system:     For...
  5. DataConduIT repeatedly crashes during high volume transactions

    Symptom DataConduIT repeatedly crashes during high volume transactions from multiple clients without an exception in the Lenel Error Log.   Inspection of the crash dump will contain an Access_Violation when trying to perform the GetAccessLeve...
  6. DataConduIT query of Lnl_Reader shows "WMI: Not Found" error in log file

    The following article discusses how to correct an error related to querying the lnl_reader object within wbem tool and it returns with an error stating WMI: Not Found.
  7. Administrator account of the Active Directory shows "Access Denied" error when receiving DataConduIT events

    Symptom  The Administrator account of the Active Directory shows the error message “Access Denied” when running the .js script to receive DataConduIT events. This error occurs only if the user's login name is empty for the account at the Active D...
  8. Encryption used to store OnGuard passwords in database

    Question   What encryption is used when passwords are stored in the OnGuard database?     Answer Internal account passwords use a salted SHA1 hash. The database password stored with the Login Driver component use an RSA RC2 encr...
  9. Violation of Primary Key constraint 'RDRIDX'

    Symptom When adding a new reader from a migrated system such as FCWNX, an error is generated that prevents the reader from being created: "Violation of Primary Key constraint 'RDRIDX'. Cannot insert duplicate key in object 'dbo.RDR_CARDF...
  10. How to set up and run an Scp Debug session running the Communication Server as an application (for short-term logging)

    How to run an Scp Debug file for short-term logging Procedure Steps 1) If the Communication Server service is installed on a computer running Windows 7 or above, User Account Control (UAC) must be disabled. Open Control Panel and select User...