Panels

How to setup a failover on a LNL-3300 with a Cobox / Lantronix Device

03/23/2018April Daniels
How to setup a failover on an LNL-3300 with a Cobox / Lantronix Device Procedure Steps Use the CoBox parameters provided in the Hardware Installation Guide (Configuring a CoBox Micro 100 Using Telnet). Set 38400 as the baud rate, e...

LNL-3300-M5 and LNL-4420 Wireless Lock Compatibility

01/26/2018April Daniels
Product Name LNL-3300-M5 and LNL-4420 Wireless Lock Compatibility  General Information The LNL-3300-M5 does support the Assa Abloy Aperio and Schlage wireless lock solutions. The Aperio hubs or Schlage gateways need to be wired to ...

How to collect an LNL-4420 crash dump

01/19/2018April Daniels
How to collect an LNL-4420 crash dump If problems occur when rebooting LNL-4420 panels or there are other instability issues with these panels, and you escalate the issue to Mercury, they may ask for a crash dump. This article addresses how to...

Lnl-4420 Panel Randomly Reboots

01/04/2018April Daniels
Symptom LNL-4420 panels randomly reboot.  Information may be lost such as masking or door schedules after the reboot. Resolution Apply firmware version 1.256 available for download by contacting support Applies To LNL-4420 pan...

Can an LNL-3300-M5 Have Standard Lenel Hardware Downstream?

11/07/2017April Daniels
Question Can an LNL-3300-M5 have standard Lenel hardware downstream? Answer The LNL-3300-M5 communicates through the M5/M3000 backplane to Reader Panel (RP) boards and Input or Output Control boards attached to the backplane. In additi...

M Series LNL-1100-20DI Firmware

11/06/2017April Daniels
Product Name M Series LNL-1100-20DI General Information Upgrading the M Series LNL-1100-20DI from firmware version 1.32.1 or earlier will render the access panel unusable. The LNL-1100-20DI has two (2) on-board processors, one for every ...

LNL-3300-ACUXL will not power up

09/28/2017April Daniels
Symptom LNL-3300-ACUXL will not power up Resolution When setting up a LNL-3300-ACUXL you may have to switch the wire (traditionally yellow) for the earth ground from terminal 2 to terminal 3 on TB1 in order for the panel to power on. ...

Inputs triggered on the LNL-1340-M2K are not seen in OnGuard

09/08/2017April Daniels
Symptom Inputs triggered  on LNL-1340-M2K are not seen in OnGuard.   Resolution Check the firmware revision of the LNL-1340-M2K.  In Alarm Monitoring, select Options > Display Device Firmware Revisions .  If Alar...

New Access Panel Not Coming Online

08/24/2017April Daniels
Symptom A newly added access panel does not come online in Alarm Monitoring.  The panel and all its added child devices display a red X in the System Status Tree. The LenelError.Log displays the following error message: TIME:   &...

Installing a Certificate on a Mercury Access Panel

08/23/2017April Daniels
Installing a certificate on a Mercury Access Panel Procedure Steps Use the Load Certificate page allows factory installed Mercury certificates to be replaced by unique custom certificates  Log into the Access Panel configuration pa...