Honeywell Integration with OnGuard 7.2 Overview OnGuard 7.2 supports the ability to communicate with Honeywell access panels and downstream devices. This document provides an overview of this support. Honeywell transition ...
02/07/2022April Daniels
X-Series panels in Alarm Monitoring show “Configuration type mismatch” when viewed in the System Tree. Procedure Steps If using OnGuard 7.5 or later, these steps apply if using X3300, X2220, X2210, or X4420 panels: Using a LNL-X3300 as an examp...
02/07/2022April Daniels
Configuring a USB Ethernet Network Interface (NIC) on LNL-X Series Controllers Overview All LNL-X Series controllers support a secondary network interface via a USB adapter. The use of this secondary NIC on the controller is to provide an alternat...
02/07/2022April Daniels
Additional Information The following links are available if the link in the PDF does not provide access to the required file downloads. BoschEventsAdd.sql BoschPanelsAdd.sql ...
02/07/2022April Daniels
OnGuard 7.5 Encryption for Controllers User Guide does not contain steps or correct names for TLS certificates to install. Procedure Steps Configure TLS Encryption Using a Default Certificate Prerequisites 1. Establish unencrypted communic...
02/07/2022April Daniels
Symptom When attempting to download firmware to downstream devices such as an LNL-1320, the download is initiated, but the device does not update to the latest firmware revision available. Resolution Launch an access panel's web configurati...
02/07/2022April Daniels
Notice for users regarding powering readers from the LNL-X4420, LNL-X2220, and the Series 3 MR52. The Reader Power Select option on the LNL-X4420, LNL-X2220, and Series 3 boards has changed. Procedure Steps When 12 VDC is applied to power the boa...
02/07/2022April Daniels
Symptom LNL-1320 Series 3 board is not coming online, while the LNL-1320 Series 2 board connects instantly when swapped. Resolution Remove all terminations from downstream devices up to the access panel. Applies To All versions of OnGuard ...
02/04/2022April Daniels
Symptom Alarms from EST3 panels are not shown in OnGuard for all double-byte languages (for example, Russian, Chinese, Japanese, Korean, Arabic, etc.). Alarm Monitoring shows junk characters in the alarms received from EST3 panels, instead of showi...