02/04/2009April Daniels
Product Name HID iCLASS Card Compatibility with HID iCLASS Programmers and Encoders General Information There are three types of HID iCLASS cards that can be sourced from Lenel: 1) Configured and programmed iCLASS cards (HID Part Number...
12/08/2008April Daniels
Symptom When using U.S. Robotics modems for Intelligent System Controller (ISC) communications, the modems appear to connect, as shown by the LEDs on the modems, but there is no audible indication the modems are connecting. Resolution To r...
11/10/2008April Daniels
How to configure Black Box IC108A for 2-wire ISC communication Procedure Steps 1) To wire the Black Box IC108A for 2-wire communication: - Connect TxA and RxA with a jumper. - Connect TxB and RxB with a jumper. - Connect TxA on the IC108A ...
10/30/2008April Daniels
How to check COM port settings Procedure Steps 1) In the Control Panel double-click System . The System Properties window opens. 2) Select the Hardware tab and click [Device Manager]. 3) In the Device Manager tree, expand Ports (COM & LPT...
10/29/2008April Daniels
Question How should the modem status LEDs appear for both host and panel modems? Answer Status LEDs for both U.S. Robotics and SECURCOMM DC336 modems are indicated below. Information for both the host and panel-end modems is listed for ea...
10/22/2008Content Creator
Question What is the difference between series 3, series 2, and series 1 hardware boards? Examples of these boards include the LNL-1100 and LNL-1200 alarm panels, and LNL-1300 and LNL-1320 reader interface modules. Answer Some of the diffe...
10/17/2008April Daniels
Symptom The following error message is displayed when you attempt to download firmware to an access panel in Alarm Monitoring (done by right-clicking on the access panel, then selecting Download Firmware ): "Failed to send firmware download ...
10/03/2008April Daniels
How to uninstall and reinstall ScanShell software Procedure Steps If you have attempted to install and configure a ScanShell 800 or 1000 device and the device is not functioning properly, follow the steps below to uninstall and reinstall the ...
06/12/2008April Daniels
How to troubleshoot a Lantronix device Procedure Steps 1) Make sure the device can be pinged by IP address by running the following command: ping If the device can be pinged, continue to the next step. If the device cannot be pinged, mak...
03/04/2008April Daniels
Symptom A "No Tamper Signal" event is displayed in Alarm Monitoring for the LNL-2020W. Resolution Verify that the correct keypad has been selected on the Reader tab in System Administration. It should be configured as LNL-2020W with tamper...