DSR will not come online after Installing the 7.6 Accessory Add-On for Assa Abloy

Procedure Name

DSR will not come online after Installing the 7.6 Accessory Add-On for Assa Abloy

Procedure Steps

1.    Confirm that the Assa Abloy add-on is installed ONLY on the comm server that the DSR is pointing to.

2.    It is recommended to install the add on using an elevated command window using the following command - msiexec /I ‘path to the setup.msi’

3.    IF after installing the add on you are still experiencing DSR’s off line you will need to register the Assa Abloy dll’s using regasm.exe 9 (C:\windows\Microsoft.net\framework\2.057)

  a.    Stop the LS Communication Server if it is not already

  b.    Navigate to the dll - ~\Program Files (x86)\OnGuard

  c.    Right click on the dll

  d.    Open with, select Look for another app

  e.    Navigate to the regasm.exe, select it and click open - If it runs without any messages come up then all is ok

  f.    After registering all Assa Abloy DLL’s Run the DSR-OnGuard Configuration Maker

  g.    Start the LS Communication Server

Applies to


Additional Information


© 2024 Honeywell International Inc. All Rights Reserved.