Wiring an external reader to an iCAM7000

How to wire an external reader to the iCAM7000

Procedure Steps

With firmware version 7.09.05 and earlier, a reader configuration card is required to flash the RW400 Reader to a 115200 baud rate. RW400 Readers will not read properly with a 57600 baud rate.

Config Card: 2000-10-00-000005
Smart Card Interface:
iCAM7000 HID RW400
12V P1-4 +VDC
TXD P2-6 GPIO2 RX
RXD P2-7 GPIO1 TX
GND P1-3 RTN

Wiegand IN Interface:
iCAM7000 HID RW400 iCAM7000 (smart card)
DATA_0 P2-3 Data 0
DATA_1 P2-4 Data 1
GND GND

Applies To

OnGuard (All versions)  

Additional Information