How to wire a RW400 Model 6121BKT0000PRGL reader for encoding

Problem Overview

How to wire an RW400 Model 6121BKT0000PRGL reader for encoding 

Detailed Description

The RW400 is shown in the OEM Device Configuration Guide with a pigtail. Model 6121BKT0000PRGL comes with a Terminal Block. Here is the correct wiring of the DB9 Pigtail Terminal:

  • Pin 2 pink GP101 (P2-7)
  • Pin 3 gray GP102 (P2-6)
  • Pin 5 black Shield Ground (P1-5)

There is a sticker under the back cover plate of the reader that shows the layout of terminal blocks.

  • P1-1 Beeper
  • P2-7 GP101
  • P1-2 Green LED
  • P2-6 GP102
  • P1-3 Ground
  • P2-5 OC/Tamper
  • P1-4 VDD
  • P2-4 Wiegand Data 0
  • P1-5 Shield Ground
  • P2-3 Wiegand Data 1
  • P1-6 Red LED
  • P2-2 GP103
  • P1-7 Hold
  • P2-1 GP104

Applies To

OnGuard (All versions)

Additional Information