Updated Articles

  1. Where is the OnGuard 8.3 Hardware Guide?

    Symptom The Hardware Guide that ships with OnGuard 8.3 lists OnGuard 8.2 in the copyright section. Resolution While OnGuard 8.3 release has been successfully tested at UL Solutions with X-Series controllers, testing of the M-S...
  2. Red X during configuration for Reports and Dashboards while using Setup Assistant

    Symptom A red cross (Failure) is displayed in Setup Assistant during OnGuard installation for ‘OnGuard Reports and Dashboard Database’ and ‘OnGuard Reports and Dashboard’ steps Resolution This error is caused due to the follow...
  3. How to connect Brother Printer model QL-720NW to Visitor Self Service

    Procedure Steps Connect the Brother printer to a networked computer using the USB port. Configure the Brother printer:    Brother Printer Setting Tool    Communication Settings    Wired LAN: IP Address: Boot Method: Static  IP Address...
  4. Upgrade Netbox to 6.2, get replication error in Global

    Upgrade Netbox to 6.2, get replication error in Global because of missing Honeywell VMS type Add missing VMS type to Global server: stage=> INSERT INTO stage_live.vmstype(vmstypeid,name) VALUES(15,'Honeywell'); Error will clear immediately ...
  5. Setup Assistant appears to “Crash” without error.

    Symptom Setup assistant appears to “Crash” or close upon being launched after install. Resolution Setup Assistant requires a connection to the database to start.  Check the application.config file in C:\ProgramData\Lnl folder to make sure there...
  6. “Events Polling Stopped” errors appear in logs

    How to identify and correct issues with event polling stopped error message
  7. RabbitMQ and NGINX uninstall and installation

    RabbitMQ and NGINX uninstall and installation This document serves as a guide for customers who want to upgrade these third-party components.  Note:  Specific versions of each component are not specified below. The Third-party Application Com...
  8. Configure Schlage Device Addressing in OnGuard

    Multi-Dropped Devices For both Schlage ENGAGE Gateways and PIMs, there are device addresses on the Schlage side, and a combined board and device addresses used in the System Administration application to define the same object. Basically, Schl...
  9. Visitor Management: Login with the Correct User Name and Password Fails if Access to the System is Disabled (DE1471)

    Problem Overview Visitor Management: Login with the Correct User Name and Password Fails if Access to the System is Disabled (DE1471) Detailed Description When the correct user name and password has been typed in and there is a failure to ...
  10. How to program an LNL-CK with firmware 1.63.0

    Procedure Steps Changes were made to the LNL-CK firmware that change the on-screen configuration for the keypad itself. You can access the configuration section by pressing the two outer keys during power up.   In firmware 1....