There are two possible symptoms that may cause the "Server Error in '/watch' Application" error message to appear:
-
Bad response after GetDirectoryList ()
call, or -
Login Driver is not running
To resolve this issue, restart the LS Open Access service. If it fails and the following message appears, "Error 1053: The service did not respond to the start or control request in a timely fashion," wait a few minutes and try restarting the LS Open Access service again.
If the error persists, check the log file (C:\Program Files (x86)\OnGuard\logs\OpenAccess.log) for the following details:
TIME: [10/27/2015 08:45:36]
SEVERITY: Error
ERROR CODE: 0x20010001
PROGRAM: Lnl.OG.LsOpenAccess
FILE: Lnl.OG.LsOpenAccess.cpp (LINE 331)
DETAILS: Internal logic error.: CLsOpenAccessApp::OpenDatabase: LenelOpen() failed to open database; DSN: LENEL70MLenel.
TIME: [10/27/2015 08:45:36]
SEVERITY: Error
ERROR CODE: 0x20010001
PROGRAM: Lnl.OG.LsOpenAccess
FILE: Lnl.OG.LsOpenAccess.cpp (LINE 145)
DETAILS: Internal logic error.: Cannot open the database. Verify the ACS.ini, ODBC, Login Driver, and that the Database Server is running.
Restart the LS Login Driver service.
OnGuard WATCH