LNVR with firmware revision 6.4.500 does not appear online and LnrCapSvc cannot be stopped

Symptom

The following symptoms might be seen on an LNVR with firmware revision 6.4.500:

  • The LNVR might not appear online in Alarm Monitoring.
  • An attempt to stop the LnrCapSvc service might not actually stop the service.
  • When the LnrCapSvc service is started, its memory utilization might rise to approximately 30 MB, then stop rising.

Resolution

To resolve this issue, follow these steps:

  1. Stop all LNVR services. If the LnrCapSvc service cannot be stopped using Windows Services, use Task Manager to end the process.
  2. Delete the following file from the LNVR:
    %ProgramFiles%\Common Files\Lenel\LnrJpCap.dll
  3. Start all LNVR services.
  4. Restart the LS Communication Server service.

Applies To

OnGuard 2010 (6.4.500)
LNVR 6.4.500

Additional Information

The OnGuard 2010 Technology Update also corrects this issue.