LNL-8000 Port Configuration

Symptom

LNL-8000 Port 1 is not communicating with OnGuard.

Resolution

Controllers*

Downstream Boards Series*

LNL-8000

(Rev ? – 1.01)

LNL-8000

(Rev C¹ – 2.01.0)

LNL- 8000

(Rev C² – 2.01.0)



Port 1

Port 2-9

Port 1

Port 2-9

Port 1

Port 2-9

LNL-3300 (EP2500)

S2

Yes

Yes

No

Yes

Yes

Yes

S3

Yes

Yes

No

Yes

Yes

Yes

LNL-4420 (EP4502)

S2

Yes

Yes

No

Yes

Yes

Yes

S3

Yes

Yes

No

Yes

Yes

Yes

LNL-X3300 (LP2500)

S2

Yes

Yes

No

Yes

Yes

Yes

S3

No

Yes

No

Yes

Yes

Yes

LNL-X4420 (LP4502)

S2

Yes

Yes

No

Yes

Yes

Yes

S3

Yes

Yes

No

Yes

Yes

Yes


  • Rev C¹: Resistors R20 and R22 are NOT installed. Therefore, Port 1 will not function. Use new Rev C boards.


  • Rev C²: Resistors R20 and R22 are installed. This board works with all the controllers (see Note below).


  • Old LNL-8000 boards with U2 rev 1.01. LNL-X3300


Note: Not tested with all Controllers and downstream combinations.


Applies To


Additional Information


Copyright © 2024 Carrier. All rights reserved.