Panels

How do I transfer the warranty and ownership of a Dell product from one owner to another owner?

06/04/2009April Daniels
Question How do I transfer the warranty and ownership of a Dell product from one owner to another owner? Answer For transfer of warranty and ownership in the United States , navigate to the site below: https://support.dell.com/support/topi...

How to replace firmware files for Lenel Reader Interface Modules (RIMs) in an OnGuard installation

06/02/2009April Daniels
How to replace firmware files for Lenel Reader Interface Modules (RIMs) in an OnGuard installation Procedure Steps Complete the following steps to replace firmware files and update firmware for all currently supported Lenel reader interface mod...

How to replace firmware files for Lenel access panels in an OnGuard installation

06/02/2009April Daniels
How to update firmware for a Lenel access panel Procedure Steps Complete the following steps to replace firmware files and update the firmware for all currently supported Lenel access panels: 1) Obtain the correct revision of the firmware for ...

How to connect and initially configure an LNL-2220 or LNL-3300 via the Web configuration page

05/08/2009April Daniels
How to connect and initially configure an LNL-2220 or LNL-3300 access panel via the Web configuration page Procedure Steps 1) Configure the computer IP address in the range of 192.168.0.2 to 192.168.0.254, except for 192.168.0.251 as this addr...

How do I configure downstream devices not connected to port 2 when I promote my access panel to an LNL-2220 or LNL-3300 in System Administration?

05/06/2009April Daniels
Question How do I configure downstream devices not connected to port 2 when I promote my access panel to an LNL-2220 or LNL-3300 in System Administration? Answer When promoting an LNL-500, LNL-1000, or LNL-2000 access panel to an LNL-2220 or...

''Device Type Mismatch'' error on reader connected to LNL-1300 with firmware revision 1.38 and higher

02/19/2009April Daniels
Symptom After upgrading the firmware on an LNL-1300 from a version lower than 1.38 to revision 1.38 or higher, you may find the reader connected to the LNL-1300 appears online in the System Status Tree in Alarm Monitoring, but with a status of "...

HID iCLASS Card Compatibility with HID iCLASS Programmers and Encoders

02/04/2009April Daniels
Product Name HID iCLASS Card Compatibility with HID iCLASS Programmers and Encoders General Information There are three types of HID iCLASS cards that can be sourced from Lenel: 1) Configured and programmed iCLASS cards (HID Part Number 2...

No sound from U.S. Robotics modems when attempting to connect

12/08/2008April Daniels
Symptom When using U.S. Robotics modems for Intelligent System Controller (ISC) communications, the modems appear to connect, as shown by the LEDs on the modems, but there is no audible indication the modems are connecting. Resolution To res...

How to configure Black Box IC108A for 2-wire ISC communication

11/10/2008April Daniels
How to configure Black Box IC108A for 2-wire ISC communication Procedure Steps 1) To wire the Black Box IC108A for 2-wire communication: - Connect TxA and RxA with a jumper. - Connect TxB and RxB with a jumper. - Connect TxA on the IC108A to...

How to check COM port settings

10/30/2008April Daniels
How to check COM port settings Procedure Steps 1) In the Control Panel double-click System . The System Properties window opens. 2) Select the Hardware tab and click [Device Manager]. 3) In the Device Manager tree, expand Ports (COM & LPT) ...