How to configure an OnGuard workstation for a Lenel ILS Mobile Configurator

How to configure an OnGuard workstation for a Lenel ILS Mobile Configurator

Procedure Steps

Prerequisites:
- The OnGuard workstation is running Microsoft Windows XP or later, with an available USB port.
- The OnGuard workstation has the Communication Server service installed.

If the workstation is running Microsoft Windows XP or Windows Server 2003,
complete steps 1 - 4:

1) Download and install Microsoft ActiveSync 4.5 from microsoft.com 

2) In System Administration, create and configure the ILS Offline panel.

3) Stop the LS Communication Server service if it is running.

4) Start the Communication Server application.

If the workstation is running Microsoft Windows Vista, Windows 7 or Windows Server 2008,
complete steps 5 - 7:

5) Download and install Windows Mobile Device Center 6.1 from microsoft.com 

6) From System Administration, add and configure the ILS Offline panel.

7) Ensure the Communication Server is running, either as a service or an application.

Applies To

OnGuard 2010 (6.4.500) or later
Lenel ILS

Additional Information

None