Thick Client Applications

How to remove the machine name ''FAILOVER'' on a system that is no longer clustered

10/22/2007April Daniels
How to remove the machine name "FAILOVER" on a system that is no longer clustered Procedure Steps If a server was once part of an NEC Cluster, the LS Communication Server may still be referenced as FAILOVER. You can check this by l...

How to set up and run an Scp Debug session using ACS.INI settings (for long-term logging)

10/22/2007April Daniels
How to set up and run an Scp Debug session using ACS.INI settings (for long-term logging) Procedure Steps 1) If the Communication Server service is installed on a computer running Windows Vista, Windows 7, or Windows Server 2008, User Accoun...

HTTP 500 - Internal Server Error when logging In to browser-based applications

10/22/2007April Daniels
Symptom HTTP 500 Internal Server Error when logging into browser-based applications Resolution An HTTP 500 error may be caused by an incorrect configuration of the ASP.net version.   ASP.net version should be set to 4.0 or highe...

FIPS Key Generator utility updated to meet updated FIPS 140-2 requirements

12/31/1969April Daniels
Product Name FIPS Key Generator General Information The FIPS Key Generator utility on version 21 of the Supplemental Materials disc (which shipped with OnGuard 7.3) has been superseded by a new version available on the Lenel Partn...

''License violation. 97697FDC-E7F1-40A1-B767-EBCE557A853C is not licensed for use with Open Access.'' message appears when logging into OnGuard WATCH

11/03/2015
 Symptom This error message indicates that the OnGuard license file does not have the Open Access "OnGuard WATCH" feature set to true . Resolution Request an updated OnGuard license file. ...

''This webpage is not available - ERR_CONNECTION_TIMED_OUT'' message appears when accessing the OnGuard WATCH web page

11/03/2015
 Symptom There are two possible causes that can create this error message to appear when trying to access the OnGuard WATCH web page: The port number ( 8080 ) is missing in the URL The LS Web Service (nginx) is not...

''This webpage is not available - ERR_CONNECTION_REFUSED'' message appears when accessing the OnGuard WATCH web page

11/03/2015
 Symptom This issue occurs if the LS Web Service (nginx) is not running. Resolution Start or restart the LS Web Service.   In the Task Manager list of processes, two nginx processes (with the g...

''504 Gateway Time-out - nginx/1.6.1'' message occurs when accessing the OnGuard WATCH web page

11/03/2015
 Symptom There are three possible causes that can create this error message when trying to access the OnGuard WATCH web page: The LS Web Proxy Service is not running The LS Open Access Service is not running The...

''The remote server returned an error: (500) Internal Server Error'' message appears when accessing the OnGuard WATCH web page

11/03/2015
 Symptom There are two possible symptoms that may cause this error message to appear: Bad response after GetDirectoryList () call, or Login Driver is not running Resolution To resolve...

Server Error in '/watch' Application'' occurs when accessing the OnGuard WATCH web page

11/03/2015
 Symptom There are two possible symptoms that may cause the "Server Error in '/watch' Application" error message to appear: Bad response after GetDirectoryList () call, or Login Driver is not running ...